A full list of CNIE Thermal Analyses equipment
TGA7 (Perkin Elmer)

Ranges of use:
- Temperature: : 30 to 1000°C
- Purge gas: switchable between N2 and air
High Balance Sensitivity
- Balance is Thermally Isolated From Furnace
- Fast Cool Down Increases Throughput
- High Speed Microprocessor for Control of All Functions
- Built-in Diagnostics Continuously Monitor and Analyze All System Functions
- Specification please refer to Pyris 1 TGA
AD 6000 Ultra MicroBalance (Perkin Elmer)

The PerkinElmer® AD 6000 balance auto-balance offers a wide range of features, including high performance, fully automated operation, and user convenience.
Features/Benefits
- High resolution to 0.1 µg
- Capacity: 1g
- Weighing range of 0.1 µg to 1000 mg
- Automatic calibration, tare and weight range routines simplify operation
- RS-232 option allows connection to instruments for direct weight reading
Pyris 1 TGA-MS (Perkin Elmer & Hiden)

Temperature: 30 to 1000°C, Purge gas: N2
TGA Design: A vertical design with a high sensitivity balance and quick response furnace. The balance is located above the furnace and is thermally isolated from it. A precision hang-down wire is suspended from the balance down into the furnace. At the end of the hang-down wire is the sample pan. The sample pan’s position is reproducible.
Sample Atmosphere: Static or dynamic, including nitrogen or air
Standard Furnace Temperature Range: Subambient to 1000 °C
Scanning Rates: 0.1 °C/minute to 200 °C/minute
Temperature Precision: ±2 °C
BalanceTare: Reproducible to ±2 μg
Sensitivity: 0.1 μg
Accuracy: Better than 0.02%
Precision: 0.001%
Capacity: 1300 mg
Hang-down wires: High temperature quartz
Sample pans: Platinum with capacity of 60 μL
Sample mass range: Up to 1300 mg
Cooling: Forced air cooled with an external fan and internal booster purge; 1000 °C to 40 °C in less than 15 minutes under normal operation
Hyphenated techniques: Compatible with mass spectrometers (MS)
Gas switching: Fast, thorough and efficient due to reduced furnace volume. Less than 3 minutes to purge the sample area of ambient gases (remove 99% of oxygen) and replace the volume with an inert purge gas. 10 minutes to achieve a 99.99% oxygen-free environment.
SC 8000 (Perkin Elmer)

Temperature: -80 to 750°C, Purge gas: N2 or He
Typical applications:
Isothermal kinetics studies - Measure samples at a true constant temperature
UV curing in polymers - Rapid response measures even the fastest cures
Process and product improvement - Demanding industrial and academic research
Features & Benefits:
All new double-furnace design delivers the most accurate heat-flow measurements
Symmetrical design ensures that instrument response from sample and reference pans are always identical
Non-oxidating, chemically resistant platinum alloy furnaces
Controlled heating and cooling for the most accurate result
Maximum Temperature 750 °C
Minimum Temperature -80 °C
Purge gas: N2 or He