PHP Code
Using the PHP code extracts allows Academic Staff Profiles to be displayed in a number of different styles including the tabbed format shown below - the data is provided dynamically from the IRIS application, while maintaning the consistent look and feel of your site.
Dr Spyros Tzamtzis
Telephone:
02076794517Email:
s.tzamtzis@ucl.ac.ukAddress:
Department of Mechanical Engineering UCL Department of Mechanical Engineering ,
Torrington Place ,
London,
WC1E 7JEAppointments:
Research Associate, Dept of Mechanical Engineering, Faculty of Engineering Science

Research Activities
- Assessment of Cardiovascular Prostheses
- Design of Artificial Heart Valves
- Transcatheter Heart Valve
Recent Publications
Displaying 13 most recent publications. For the full list please visit UCL Discovery
- Tzamtzis S,Viquerat J,Yap J,Mullen MJ,Burriesci G (2013) Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med Eng Phys, 35(1), 125 - 130. 10.1016/j.medengphy.2012.04.009.
- Rahmani, B ,Tzamtzis S,Ghanbari H,Burriesci G,Seifalian AM (2012) A novel aortic valve prosthesis made of a new nanocomposite polymer: hydrodynamic assessment. Cardiology, 121(2), 132 - 133.
- Rahmani B,Burriesci G,Mullen M,Seifalian A,Tzamtzis S,Yap J (2012) A New Generation Transcatheter Heart Valve with a Novel Nanocomposite Material and Fully Retrievable Design. JACC: Cardiovascular Interventions, 60(17), B34. 10.1016/j.jacc.2012.08.126.
- Rahmani B,Tzamtzis S,Ghanbari H,Burriesci G,Seifalian AM (2012) Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer. J Biomech, 45(7), 1205 - 1211. 10.1016/j.jbiomech.2012.01.046.
- Tzamtzis S,Zhang H,Xia M,Babu NH,Fan Z (2011) Recycling of high grade die casting AM series magnesium scrap with the melt conditioned high pressure die casting (MC-HPDC) process MAT SCI ENG A-STRUCT, 528(6), 2664 - 2669. 10.1016/j.msea.2010.12.001.
- Tzamtzis S,Ghanbari H,Seifalian A,Burriesci G (2010) A new generation aortic valve device for transcatheter implantation. Cardiology, 115(4), 292. 10.1159/000308357.
- Tzamtzis S,Zhang H,Babu NH,Fan Z (2010) Microstructural refinement of AZ91D die-cast alloy by intensive shearing MAT SCI ENG A-STRUCT, 527(12), 2929 - 2934. 10.1016/j.msea.2010.01.013.
- Barekar N,Tzamtzis S,Dhindaw BK,Patel J,Babu NH,Fan Z (2009) Processing of Aluminum-Graphite Particulate Metal Matrix Composites by Advanced Shear Technology J MATER ENG PERFORM, 18(9), 1230 - 1240. 10.1007/s11665-009-9362-5.
- Barekar NS,Tzamtzis S,Babu NH,Fan Z,Dhindaw BK (2009) Processing of Ultrafine-Size Particulate Metal Matrix Composites by Advanced Shear Technology METALL MATER TRANS A, 40A(3), 691 - 701. 10.1007/s11661-008-9750-8.
- Tzamtzis S,Zervides C,Ghanbari H,Seifalian A,Burriesci G (2009) Minimally Invasive Aortic Valve Prosthesis..
- Tzamtzis S,Zhang H,Liu G,Wang Y,Babu NH,Fan Z (2009) MELT CONDITIONED HIGH PRESSURE DIE CASTING (MC-HPDC) OF Mg-ALLOYS MAGNESIUM TECHNOLOGY 2009, 91 - 96.
- Tzamtzis S,Barekar NS,Babu NH,Patel J,Dhindaw BK,Fan Z (2009) Processing of advanced Al/SiC particulate metal matrix composites under intensive shearing - A novel Rheo-process COMPOS PART A-APPL S, 40(2), 144 - 151. 10.1016/j.compositesa.2008.10.017.
- Babu NH,Tzamtzis S,Barekar N,Patel JB,Fan Z (2008) Fabrication of Metal Matrix Composites under Intensive Shearing SEMI-SOLID PROCESSING OF ALLOYS AND COMPOSITES X, 141-143, 373 - 378.
There are no biographical details to display
